Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Methods Mol Biol ; 2628: 535-553, 2023.
Article in English | MEDLINE | ID: covidwho-2243906

ABSTRACT

The detection of antibody responses using serological tests provides means to diagnose infections, follow disease transmission, and monitor vaccination responses. The coronavirus disease 2019 (COVID-19) pandemic, caused by the SARS-CoV-2 virus, highlighted the need for rapid development of robust and reliable serological tests to follow disease spreading. Moreover, the rise of SARS-CoV-2 variants emphasized the need to monitor their transmission and prevalence in the population. For this reason, multiplex and flexible serological assays are needed to allow for rapid inclusion of antigens representing new variants as soon as they appear. In this chapter, we describe the generation and application of a multiplex serological test, based on bead array technology, to detect anti-SARS-CoV-2 antibodies in a high-throughput manner, using only a few microliters of sample. This method is currently expanding to include a multi-disease antigen panel that will allow parallel detection of antibodies towards several infectious agents.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Serologic Tests/methods , COVID-19 Testing , Antibodies, Viral , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus
2.
PLoS One ; 17(1): e0262169, 2022.
Article in English | MEDLINE | ID: covidwho-1633137

ABSTRACT

Current SARS-CoV-2 serological assays generate discrepant results, and the longitudinal characteristics of antibodies targeting various antigens after asymptomatic to mild COVID-19 are yet to be established. This longitudinal cohort study including 1965 healthcare workers, of which 381 participants exhibited antibodies against the SARS-CoV-2 spike antigen at study inclusion, reveal that these antibodies remain detectable in most participants, 96%, at least four months post infection, despite having had no or mild symptoms. Virus neutralization capacity was confirmed by microneutralization assay in 91% of study participants at least four months post infection. Contrary to antibodies targeting the spike protein, antibodies against the nucleocapsid protein were only detected in 80% of previously anti-nucleocapsid IgG positive healthcare workers. Both anti-spike and anti-nucleocapsid IgG levels were significantly higher in previously hospitalized COVID-19 patients four months post infection than in healthcare workers four months post infection (p = 2*10-23 and 2*10-13 respectively). Although the magnitude of humoral response was associated with disease severity, our findings support a durable and functional humoral response after SARS-CoV-2 infection even after no or mild symptoms. We further demonstrate differences in antibody kinetics depending on the antigen, arguing against the use of the nucleocapsid protein as target antigen in population-based SARS-CoV-2 serological surveys.


Subject(s)
COVID-19/pathology , Immunity, Humoral , Adult , Antibodies, Neutralizing/blood , Antibodies, Neutralizing/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , Asymptomatic Infections/epidemiology , COVID-19/immunology , COVID-19/virology , Female , Health Personnel , Humans , Immunoglobulin G/blood , Immunoglobulin G/immunology , Longitudinal Studies , Male , Middle Aged , Nucleocapsid/immunology , SARS-CoV-2/isolation & purification , SARS-CoV-2/metabolism , Severity of Illness Index , Spike Glycoprotein, Coronavirus/immunology
3.
J Intern Med ; 291(1): 72-80, 2022 01.
Article in English | MEDLINE | ID: covidwho-1443300

ABSTRACT

BACKGROUND: Emerging data support detectable immune responses for months after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and vaccination, but it is not yet established to what degree and for how long protection against reinfection lasts. METHODS: We investigated SARS-CoV-2-specific humoral and cellular immune responses more than 8 months post-asymptomatic, mild and severe infection in a cohort of 1884 healthcare workers (HCW) and 51 hospitalized COVID-19 patients. Possible protection against SARS-CoV-2 reinfection was analyzed by a weekly 3-month polymerase chain reaction (PCR) screening of 252 HCW that had seroconverted 7 months prior to start of screening and 48 HCW that had remained seronegative at multiple time points. RESULTS: All COVID-19 patients and 96% (355/370) of HCW who were anti-spike IgG positive at inclusion remained anti-spike IgG positive at the 8-month follow-up. Circulating SARS-CoV-2-specific memory T cell responses were detected in 88% (45/51) of COVID-19 patients and in 63% (233/370) of seropositive HCW. The cumulative incidence of PCR-confirmed SARS-CoV-2 infection was 1% (3/252) among anti-spike IgG positive HCW (0.13 cases per 100 weeks at risk) compared to 23% (11/48) among anti-spike IgG negative HCW (2.78 cases per 100 weeks at risk), resulting in a protective effect of 95.2% (95% CI 81.9%-99.1%). CONCLUSIONS: The vast majority of anti-spike IgG positive individuals remain anti-spike IgG positive for at least 8 months regardless of initial COVID-19 disease severity. The presence of anti-spike IgG antibodies is associated with a substantially reduced risk of reinfection up to 9 months following asymptomatic to mild COVID-19.


Subject(s)
Antibodies, Viral/blood , COVID-19/diagnosis , COVID-19/immunology , Immunity, Cellular , Immunity, Humoral , Immunoglobulin G/immunology , Reinfection , Adult , Antibodies, Viral/immunology , Asymptomatic Infections , COVID-19 Nucleic Acid Testing , COVID-19 Serological Testing , Female , Humans , Immunoglobulin G/blood , Male , Memory T Cells , Middle Aged , Pandemics , SARS-CoV-2 , Time Factors
4.
Clin Transl Immunology ; 10(7): e1312, 2021.
Article in English | MEDLINE | ID: covidwho-1321684

ABSTRACT

OBJECTIVE: The COVID-19 pandemic poses an immense need for accurate, sensitive and high-throughput clinical tests, and serological assays are needed for both overarching epidemiological studies and evaluating vaccines. Here, we present the development and validation of a high-throughput multiplex bead-based serological assay. METHODS: More than 100 representations of SARS-CoV-2 proteins were included for initial evaluation, including antigens produced in bacterial and mammalian hosts as well as synthetic peptides. The five best-performing antigens, three representing the spike glycoprotein and two representing the nucleocapsid protein, were further evaluated for detection of IgG antibodies in samples from 331 COVID-19 patients and convalescents, and in 2090 negative controls sampled before 2020. RESULTS: Three antigens were finally selected, represented by a soluble trimeric form and the S1-domain of the spike glycoprotein as well as by the C-terminal domain of the nucleocapsid. The sensitivity for these three antigens individually was found to be 99.7%, 99.1% and 99.7%, and the specificity was found to be 98.1%, 98.7% and 95.7%. The best assay performance was although achieved when utilising two antigens in combination, enabling a sensitivity of up to 99.7% combined with a specificity of 100%. Requiring any two of the three antigens resulted in a sensitivity of 99.7% and a specificity of 99.4%. CONCLUSION: These observations demonstrate that a serological test based on a combination of several SARS-CoV-2 antigens enables a highly specific and sensitive multiplex serological COVID-19 assay.

SELECTION OF CITATIONS
SEARCH DETAIL